Photo Diode Characteristics Apparatus

Photo Diode Characteristics Apparatus

Product Details:

  • Usage Laboratory, Educational institutions
  • Display Digital Panel Meter
  • Voltage 230V AC, 50Hz
  • Power 5W (max)
  • Product Type Photo Diode Characteristics Apparatus
  • Material Powder Coated Metallic Enclosure, Polycarbonate base
  • Design Table-top, compact & portable
  • Click to view more
X

Photo Diode Characteristics Apparatus Price And Quantity

  • 1 , , Unit
  • Continuously variable using rotary knob
  • Overload protection circuitry
  • I-V and V-I Characteristics, Light Intensity Variation Study
  • Factory calibrated
  • Adjustable and fixed options
  • 0C to 50C
  • 0-20 A (Current), 0-2V (Voltage)
  • Banana Sockets for easy experiment setup
  • Printed with circuit diagram and controls

Photo Diode Characteristics Apparatus Product Specifications

  • Digital Panel Meter
  • 320mm x 250mm x 110mm
  • 230V AC, 50Hz
  • Powder Coated Metallic Enclosure, Polycarbonate base
  • 5W (max)
  • Photo Diode Characteristics Apparatus
  • AC mains
  • High-sensitivity Silicon Photodiode
  • Less than 2 seconds
  • Table-top, compact & portable
  • Approx. 2.5 kg
  • Laboratory, Educational institutions
  • 2%
  • Inbuilt Adjustable Light Source
  • Continuously variable using rotary knob
  • Overload protection circuitry
  • I-V and V-I Characteristics, Light Intensity Variation Study
  • Factory calibrated
  • Adjustable and fixed options
  • 0C to 50C
  • 0-20 A (Current), 0-2V (Voltage)
  • Banana Sockets for easy experiment setup
  • Printed with circuit diagram and controls

Photo Diode Characteristics Apparatus Trade Information

  • 5 , , Unit Per Week
  • 4-5 Days

Product Description

Photo diode Characteristics Apparatus (AE 232 )

Objective :To plot a graph, Current Vs Intensity of light at different value of voltages.

Features :Instrument comprises of DC Regulated Power Supply 0-3 VDC/150mA, two round meters for voltage & current measurement, Photo diode mounted in a metal box, connections of Supplies & Photo diode brought out at 4mm Sockets. Lamp holder with 100W Bulb & 50 cm wooden plank are given with this apparatus.

Specification

Type

Analog

Model Name/Number

AE 232

Brand

ASICO

Color

Gray

Packaging Type

Corrugated Box

Display Type

Analog

I Deal In

New Only

Power Supply

AC Mains

Usage/Application

laboratory

 



Comprehensive Photodiode Analysis

Equipped with an inbuilt, continuously adjustable light source and a high-sensitivity silicon photodiode, this apparatus supports the systematic study of I-V and V-I characteristics as well as investigations into the effect of light intensity on photocurrent. With digital panel meters and a user-friendly front panel, the system offers accuracy and clarity for students and researchers alike.


Designed for Educational Excellence

Featuring robust safety measures, including overload protection and factory calibration, the apparatus is tailored for safe, long-term use in classrooms and laboratories. The printed front panel includes a circuit diagram for instructional value, while the banana socket connections ensure quick and reliable experimental setup.


Portability and Ease of Use

Packaged in a compact, powder-coated metallic enclosure with a polycarbonate base, this table-top system weighs approximately 2.5 kg and is easy to move between classrooms or laboratory benches. Powered by standard 230V AC mains with low power consumption, its ideal for institutional use.

FAQs of Photo Diode Characteristics Apparatus:


Q: How do I set up the Photo Diode Characteristics Apparatus for an experiment?

A: Simply connect your test leads via the easily accessible banana sockets. Use the adjustable or fixed photodiode mount as required for your experiment. The system powers on with standard AC mains and becomes ready for measurements in less than two seconds.

Q: What types of experiments can be performed with this apparatus?

A: The setup enables you to study I-V and V-I characteristics of a photodiode, analyze light intensity response, and observe changes in photocurrent and photovoltage using the adjustable light source. These experiments are crucial for understanding photodiode operation and applications.

Q: When should the device be recalibrated or serviced?

A: The apparatus is factory calibrated for optimal accuracy (2%). Routine recalibration is not needed for standard educational use, but annual professional servicing is recommended for heavy usage or when operating outside recommended temperature ranges (0C to 50C).

Q: Where is the apparatus most effectively used?

A: This instrument is designed for laboratory environments, particularly in educational institutions such as schools, colleges, and university departments engaged in electronics or physics experimentation.

Q: What safety features are included in the apparatus?

A: The photo diode characteristics apparatus incorporates overload protection circuitry. This safeguard prevents accidental damage to the internal electronics during unexpected voltage or current surges, enhancing operational safety for students and educators.

Q: How does the adjustable light intensity control work?

A: A rotary knob on the front panel allows you to vary the inbuilt light sources intensity smoothly and continuously. This enables precise control over the incident light on the photodiode, supporting detailed analysis of its characteristics.

Q: What are the main benefits of using this apparatus?

A: This system offers easy experiment setup, reliable overload protection, swift operation initiation, and precise digital measurements. Its portability, instructional aids, and robust construction make it ideal for both classroom demonstrations and hands-on student experiments.

Tell us about your requirement