Work Function of Diode (Richardson Law (AE 209)

Work Function of Diode (Richardson Law (AE 209)

Product Details:

  • Usage Measurement of work function of metal/semiconductor using diode and Richardson Law
  • Voltage 230 V AC, 50 Hz
  • Power 50 W
  • Display Digital Meter
  • Product Type Educational Physics Experiment Apparatus
  • Material Aluminium & MS Powder Coated
  • Design Compact modular design
  • Click to view more
X

Work Function of Diode (Richardson Law (AE 209) Price And Quantity

  • 1 Unit
  • Directly heated filament, removable
  • Banana socket terminals
  • Work function up to 5 eV
  • Physics laboratory, electronic work function measurement, educational research
  • Multi-step variable voltage control for accurate plotting
  • Room temperature to 800°C (cathode heating)
  • Set of connecting leads, user manual, thermionic diode
  • High vacuum thermal diode with replaceable cathode
  • Richardson Law (thermionic emission method)

Work Function of Diode (Richardson Law (AE 209) Product Specifications

  • Mains Electricity
  • Approx. 5 kg
  • Photoelectric Diode
  • 310 mm x 250 mm x 130 mm
  • Filament Bulb (incandescent)
  • 1% or better
  • Approx. 30 minutes
  • 50 W
  • Compact modular design
  • Aluminium & MS Powder Coated
  • Digital Meter
  • Educational Physics Experiment Apparatus
  • Measurement of work function of metal/semiconductor using diode and Richardson Law
  • 230 V AC, 50 Hz
  • Directly heated filament, removable
  • Banana socket terminals
  • Work function up to 5 eV
  • Physics laboratory, electronic work function measurement, educational research
  • Multi-step variable voltage control for accurate plotting
  • Room temperature to 800°C (cathode heating)
  • Set of connecting leads, user manual, thermionic diode
  • High vacuum thermal diode with replaceable cathode
  • Richardson Law (thermionic emission method)

Work Function of Diode (Richardson Law (AE 209) Trade Information

  • 5 Unit Per Week
  • 4-5 Days
  • Australia, South America, Eastern Europe, Western Europe, Middle East, Asia, Central America, North America, Africa
  • All India

Product Description

Work Function of Diode (Richardson Law (AE 209)

Objective :To draw the graphs between heater current vs heater resistance, Anode voltage vs anode current.

Features : Instrument comprises of DC Regulated power supply of 0-6 V & 0-300 V. Two volt meters & two current meters are mounted on the front panel. Valve diagram is printed on the panel & connection are brought out on sockets/terminals.



Versatile Experimental Range and Precision

This apparatus supports the precise measurement of work functions up to 5 eV, aligning with advanced physics laboratory and research needs. Its multi-step voltage control and digital display enable accurate extraction of thermionic emission data, supported by 1% or better accuracy. The compact, modular design enhances versatility for various educational and experimental setups.


User-Friendly Design for Laboratory Applications

Its high vacuum thermal diode with a removable, directly heated filament cathode ensures straightforward maintenance and customization for different materials. Banana socket terminals, a complete set of accessories, and a clear user manual streamline setup and operation, making it suitable both for teaching and advanced experimentation.

FAQs of Work Function of Diode (Richardson Law (AE 209):


Q: How does the Richardson Law method measure the work function using this diode apparatus?

A: The apparatus employs the thermionic emission method based on Richardsons Law. By heating the cathode to high temperatures (up to 800C), electrons are emitted according to the metals work function. The resulting current is measured and analyzed via the digital meter and voltage control, which allows for precise plotting and calculation of the work function.

Q: What is the main benefit of the replaceable cathode design?

A: The removable, directly heated filament cathode makes it easy to test different materials or replace worn components, allowing repeated and varied experiments without the need to replace the entire device, thus extending its usability and cost-effectiveness in laboratory settings.

Q: When is this apparatus typically used, and for what applications?

A: It is commonly used in academic and research institutions for physics education, work function measurements, and experiments involving electronic emission. Its precision and flexibility make it suitable for both basic instructional labs and advanced research projects focused on electronic work functions.

Q: Where can this apparatus be implemented and who are its typical users?

A: This work function measurement system is ideal for physics laboratories, university teaching environments, and research facilities. It serves educators, students, and researchers interested in exploring electron emission and material science.

Q: What is the process of setting up and operating the apparatus?

A: To operate, connect the components using the provided leads, ensure the cathode is properly installed, and plug into a 230 V AC supply. Adjust the cathode heating to the desired temperature using the variable control, and conduct measurements as indicated in the user manual. Data is collected and displayed digitally for analysis.

Q: How does multi-step variable voltage control enhance experiment accuracy?

A: The multi-step variable voltage control allows for fine regulation of the electrical potential applied to the diode, enabling precise mapping of current versus temperature or voltage. This control aids in gathering detailed data essential for accurate determination of the work function.