VSWR Meter

VSWR Meter

Product Details:

  • Voltage 9V battery powered
  • Usage Measurement of Voltage Standing Wave Ratio (VSWR) in RF applications
  • Power 9V DC
  • Display Analog meter
  • Product Type VSWR Meter
  • Material High impact ABS plastic
  • Design Portable, compact design
  • Click to view more
X

VSWR Meter Price And Quantity

  • 1 Unit
  • High sensitivity for low power measurements
  • 1 MHz to 500 MHz
  • Up to 100W
  • 50 Ohms / 75 Ohms selectable
  • Radio, TV, communication equipment testing
  • Factory calibrated
  • Matte black
  • -20°C to 70°C
  • BNC / N-Type (depends on model)
  • 0°C to 50°C
  • Complies with relevant RF measuring standards
  • Bench top or hand-held
  • Standard indoor use

VSWR Meter Product Specifications

  • Approx. 400 g
  • Measurement of Voltage Standing Wave Ratio (VSWR) in RF applications
  • Battery operated
  • 9V battery powered
  • 9V DC
  • VSWR Meter
  • Crystal Detector
  • Approx. 2 hours
  • High impact ABS plastic
  • Analog meter
  • Portable, compact design
  • 200 x 100 x 80 mm
  • 5% or better
  • High sensitivity for low power measurements
  • 1 MHz to 500 MHz
  • Up to 100W
  • 50 Ohms / 75 Ohms selectable
  • Radio, TV, communication equipment testing
  • Factory calibrated
  • Matte black
  • -20°C to 70°C
  • BNC / N-Type (depends on model)
  • 0°C to 50°C
  • Complies with relevant RF measuring standards
  • Bench top or hand-held
  • Standard indoor use

VSWR Meter Trade Information

  • 5 Unit Per Week
  • 4-5 Days
  • Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Africa, Central America, Asia
  • All India

Product Description

As a world renowned organization, we are engrossed in offering VSWR Meter. This meter is used for measuring the standing wave ration in a transmission line and demanded for conducting various physics experiments. The meter provided by us is manufactured using quality-assured basic components with the aid of advanced methodology as per the set quality standards. Further, this meter is tested on various parameters to ensure its precise use. Moreover, we offer this VSWR Meter to our clients in several specifications as per their requirement at industrial-leading prices.

Features:

  • Detect less measuring
  • Light weight and easy in holding
  • Longer working life
  • Energy efficient

VSWR Meter.
It is high gain voltage amplifier tuned at the center frequency of 1 KHz. It is used for Measuring VSWR, Attenuation and total mismatch on the line.
microvolt Amplifier Type: High gain tuned at one frequency Frequency: 1 Khz Sensitivity: 0.1 at 200 ohms for full scale Band width: 25-30HzRange: 60 dB min. in 10 dB Scale Accuracy: 0.15 dB on one range Meter Linearity: 1% of full scale Scale-selector: Normal, Expander Gain Control: Coarse & fine Input: 



Superior Sensitivity & Accuracy

Utilizing a high-sensitivity crystal detector, this meter ensures precise results even with low-power RF signals. Accuracy is maintained within 5% or better, enabling reliable testing for both laboratory engineers and field technicians.


Versatile Connectivity & Impedance

Connector types are available in BNC or N-Type, adaptable to various testing setups. The selectable impedance (50 Ohms or 75 Ohms) allows compatibility with multiple RF systems, making it a suitable choice across diverse communication equipment.


Compact, Rugged & Portable Design

Made from high-impact ABS plastic and finished in matte black, the meter is lightweight (approx. 400g) and compact (200 x 100 x 80 mm). Its design supports convenient hand-held or bench top use. The battery-powered operation provides flexibility and mobility, ideal for on-site usage.

FAQs of VSWR Meter:


Q: How do I select the appropriate impedance for my measurements with this VSWR meter?

A: You can switch between 50 Ohms and 75 Ohms impedance settings, allowing you to match the requirements of your equipment. Refer to your devices specifications before selecting the corresponding impedance to ensure accurate VSWR readings.

Q: What type of applications can this VSWR meter be used for?

A: This meter is designed for testing radio, TV, and various communication equipment, making it ideal for lab technicians, field engineers, and service professionals assessing RF signal quality and system performance.

Q: When should I calibrate the VSWR meter?

A: The meter comes factory calibrated and is ready to use upon delivery. Normally, recalibration is not necessary unless specified by regulatory requirements or after exposure to extreme operating conditions.

Q: Where can this VSWR meter be used effectively?

A: Its suitable for standard indoor environments, in labs, workshops, or on-site testing locations. Its portable, sturdy design makes it practical for both stationary bench top and hand-held use during equipment maintenance or installations.

Q: What steps are involved in measuring VSWR with this meter?

A: Connect your RF source and load to the meter using compatible BNC or N-Type connectors. Select the correct impedance, power on the device, and read the VSWR value directly from the analog display. For accurate results, ensure proper connections and power range compatibility.

Q: What benefits does the matte black ABS construction offer?

A: The matte black, high-impact ABS plastic casing provides durability, scratch resistance, and a professional appearance, protecting the meter during field use and transport.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Microwave Lab Experiments' category