Transformer characteristics Apparatus

Transformer characteristics Apparatus

Product Details:

  • Power 230V AC, 50Hz
  • Usage Laboratory transformer characteristics experiments
  • Display Analog Meter Display
  • Voltage Primary: 0-230V AC, Secondary: 0-15V AC
  • Product Type Transformer Characteristics Apparatus
  • Material Powder coated mild steel cabinet, high quality copper windings
  • Design Table top, modular panel-mounted design
  • Click to view more
X

Transformer characteristics Apparatus Price And Quantity

  • 1 Unit
  • Color-coded banana sockets for easy connection
  • Connecting wires, circuit diagram, instruction manual
  • Up to 5 Amps (secondary circuit)
  • Indoor Laboratory
  • 50 Hz
  • Air-cooled
  • Clear silk-screened circuit diagram and labeling
  • 1 kVA (typical for laboratory use)
  • Fitted with MCB (Miniature Circuit Breaker) and fuse protection
  • Enamelled copper winding

Transformer characteristics Apparatus Product Specifications

  • Table top, modular panel-mounted design
  • Powder coated mild steel cabinet, high quality copper windings
  • 420 mm x 300 mm x 150 mm
  • Mains AC supply
  • Primary: 0-230V AC, Secondary: 0-15V AC
  • Analog Voltmeters and Ammeters
  • Analog Meter Display
  • High precision measurement, 1% FSD
  • Laboratory transformer characteristics experiments
  • Transformer Characteristics Apparatus
  • 230V AC, 50Hz
  • Approx. 9 kg
  • Color-coded banana sockets for easy connection
  • Connecting wires, circuit diagram, instruction manual
  • Up to 5 Amps (secondary circuit)
  • Indoor Laboratory
  • 50 Hz
  • Air-cooled
  • Clear silk-screened circuit diagram and labeling
  • 1 kVA (typical for laboratory use)
  • Fitted with MCB (Miniature Circuit Breaker) and fuse protection
  • Enamelled copper winding

Transformer characteristics Apparatus Trade Information

  • 5 Unit Per Week
  • 4-5 Days
  • All India

Product Description

TRANSFORMER CHARACTERISTIC APPARATUS (AE 265)

Objective:
Transformer Characteristics Apparatus has been designed to calculate the input current, output current, input power & output power.

The instrument comprises of the following built in parts:

 

  • Variable AC power supply of 220V.
  • Step down transformer of 15V/ 500 mA.
  • Different type of load resistances (25ohm - 1kohm) selectable through band switch with output on sockets are provided on the front panel.
  • Four round meters (0-300V, 0-15mA, 0-500mA & 0-15V AC) are mounted on the front panel to measure AC voltage & current.  

 

 



Comprehensive Laboratory Solution

The transformer apparatus delivers everything required for in-depth transformer characteristic experiments. With clear labeling, color-coded terminals, and provided wires, setup and experimentation are straightforward. High-quality analog meters display real-time voltage and current readings, while robust components ensure long-term durability in academic settings.


Enhanced Safety and Reliability

Operational safety is at the forefront with integrated MCB and fuse protection, helping to prevent equipment damage and ensure user security. The air-cooled system and powder-coated mild steel body enhance reliability and extend the apparatuss lifespan, making it a dependable option for repeated laboratory use.

FAQs of Transformer characteristics Apparatus:


Q: How is the transformer characteristics apparatus used in laboratory experiments?

A: This apparatus is designed for students and researchers to study and measure various transformer parameters, such as voltage, current, and efficiency, using safe and clearly marked test points. Simply connect the provided wires to the color-coded banana sockets, follow the supplied circuit diagram, and observe readings on the analog meters.

Q: What safety features are included in the transformer apparatus?

A: The unit is equipped with a Miniature Circuit Breaker (MCB) and fuse protection, which safeguard both the operator and the equipment against electrical faults such as overloads or short circuits during operation.

Q: When should I use this transformer apparatus in my curriculum?

A: This equipment should be used during practical lab sessions on transformer characteristics, transformer testing, and AC circuit analysis. Its ideal for engineering colleges, vocational institutions, and technical training programs focusing on electrical machines.

Q: Where can this apparatus be installed and operated effectively?

A: The transformer apparatus is intended exclusively for indoor laboratory settings where students can safely perform experiments on table tops with a stable 230V AC mains supply.

Q: What accessories are provided with the transformer characteristics apparatus?

A: Each unit is supplied with connecting wires, a detailed circuit diagram, and a comprehensive instruction manual to facilitate easy assembly, operation, and interpretation of results.

Q: What are the main benefits of using this apparatus for teaching and research?

A: Key benefits include accurate, high-precision analog measurements, user-friendly modular design, enhanced safety features, and durable constructionall of which make it an excellent resource for teaching fundamental transformer concepts and conducting reliable lab experiments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Analog Lab Training Modules' category