Product Details:

  • Usage Educational, Laboratory, Calibration
  • Voltage 0-10V (as Voltmeter); 0-2A (as Ammeter) depending on conversion
  • Display Analog scale
  • Power Passive (no external power required)
  • Product Type Demonstration Kit/Instrument
  • Material Acrylic, copper, metal alloys
  • Design Transparent base with labeled terminals
  • Click to view more
X

Conversion of Galvanometer to Voltmeter and Ammeter Price And Quantity

  • 1 Unit
  • Factory calibrated, user adjustable
  • 0C to 50C
  • Protective acrylic cover
  • Indoor, educational labs
  • 4 mm banana sockets
  • Included
  • Typically 100 A/div (for galvanometer)
  • Dual scale for ampere and voltmeter conversion
  • High precision resistance (shunt and series resistors)
  • Bench-top
  • Knife-edge pointer for accurate reading

Conversion of Galvanometer to Voltmeter and Ammeter Product Specifications

  • 150 mm x 90 mm x 60 mm (approx.)
  • Moving coil galvanometer
  • Demonstration Kit/Instrument
  • High accuracy, usually up to 1% of full scale
  • Educational, Laboratory, Calibration
  • Approx. 350 grams
  • Acrylic, copper, metal alloys
  • Not required (operates on circuit input)
  • Analog scale
  • Passive (no external power required)
  • Not applicable (passive instrument)
  • Transparent base with labeled terminals
  • 0-10V (as Voltmeter); 0-2A (as Ammeter) depending on conversion
  • Factory calibrated, user adjustable
  • 0C to 50C
  • Protective acrylic cover
  • Indoor, educational labs
  • 4 mm banana sockets
  • Included
  • Typically 100 A/div (for galvanometer)
  • Dual scale for ampere and voltmeter conversion
  • High precision resistance (shunt and series resistors)
  • Bench-top
  • Knife-edge pointer for accurate reading

Conversion of Galvanometer to Voltmeter and Ammeter Trade Information

  • 5 Unit Per Week
  • 4-5 Days
  • Australia, South America, Eastern Europe, Western Europe, Middle East, Asia, Central America, North America, Africa
  • All India

Product Description

Conversion of Galvanometer into a Voltmeter and Ammeter (AE 247 )

Features : Instrument comprises of DC Regulated power supply of 0-5V. Three round moving coil meters (one voltmeter, one milliammeter & one galvanometer). Three shunts, three Resistances are mounted on front panel.



Effortless Conversion and Educational Value

Quickly convert the galvanometer to either a voltmeter or an ammeter simply by integrating the included precision resistors. This kit is perfect for instructional demonstrations in educational and laboratory environments, providing clarity and hands-on experience for students learning basic measurement principles.


Designed for Precision and Safety

High-quality components including a knife-edge pointer, dual-scale markings, and acrylic cover ensure accurate readings and reliable protection. Factory calibration with user adjustments enhances measurement confidence, while the robust, transparent design allows clear visibility of internal components for better understanding.


User-Friendly and Durable Construction

With 4 mm banana sockets, bench-top mounting, and an instruction manual, setup is straightforward even for beginners. The instrument is made from durable acrylic, copper, and metal alloys, ensuring longevity under frequent educational or laboratory useall without needing an external power source.

FAQs of Conversion of Galvanometer to Voltmeter and Ammeter:


Q: How do I convert the galvanometer into a voltmeter or ammeter?

A: To convert the galvanometer, simply connect the provided precision series resistor to use it as a voltmeter (measuring 010V) or attach the precision shunt resistor for ammeter functionality (measuring up to 2A). Follow the step-by-step instructions included in the manual to ensure correct configuration.

Q: What components are included in the conversion kit?

A: The kit includes a moving coil galvanometer (100 A/div), high-precision shunt and series resistors, 4 mm banana sockets, a knife-edge pointer, protective acrylic cover, and an instruction manual for easy reference.

Q: When should I recalibrate the converted instrument?

A: Although the instrument comes factory calibrated, you may choose to recalibrate after frequent usage, after changing resistors, or if the readings deviate from expected values. Calibration details are provided in the included manual.

Q: Where is this conversion kit best used?

A: It is ideally designed for indoor settings such as educational laboratories, physics classrooms, and calibration workshops, allowing both students and instructors to conduct hands-on experiments and demonstrations with accuracy.

Q: What are the major benefits of using this conversion kit?

A: The kit offers high accuracy (1%), user adjustability, clear dual scales, and passive operationrequiring no external power. Its robust, transparent build and safety features make it highly reliable for educational and calibration purposes.

Q: How does the knife-edge pointer and dual scale improve accuracy?

A: The knife-edge pointer minimizes parallax error, allowing precise alignment with the scale markings. The dual-scale display facilitates easy switching between voltage and current measurements for enhanced clarity and convenience.