SCR Characteristics Apparatus

SCR Characteristics Apparatus

Product Details:

  • Power 230V AC, 50Hz
  • Voltage 0-30V DC (variable), 230V AC main supply
  • Display Analog/ Digital meters
  • Usage For studying V-I characteristics of SCR (Silicon Controlled Rectifier)
  • Product Type Educational Laboratory Apparatus
  • Material Hard plastic and superior quality electronic components
  • Design Compact, table-top design with secured connections
  • Click to view more
X

SCR Characteristics Apparatus Price And Quantity

  • 1 Unit
  • Dual range analog/digital ammeter and voltmeter
  • 0-15V DC (variable through potentiometer)
  • Measurement and analysis of SCR static characteristics
  • 0-500 mA
  • Short circuit and overload protection
  • Bench-top
  • 10°C to 40°C
  • Connecting wires, user manual
  • General purpose SCR (TYN612 or equivalent)
  • Provided for easy measurement and observation

SCR Characteristics Apparatus Product Specifications

  • Approx. 2.5 kg
  • 230V AC, 50Hz
  • Compact, table-top design with secured connections
  • 0-30V DC (variable), 230V AC main supply
  • In-built detector circuit for SCR operation
  • Analog/ Digital meters
  • Hard plastic and superior quality electronic components
  • 350 mm x 275 mm x 125 mm
  • Educational Laboratory Apparatus
  • High accuracy for SCR parameter measurements
  • For studying V-I characteristics of SCR (Silicon Controlled Rectifier)
  • Electric (Mains operated)
  • Dual range analog/digital ammeter and voltmeter
  • 0-15V DC (variable through potentiometer)
  • Measurement and analysis of SCR static characteristics
  • 0-500 mA
  • Short circuit and overload protection
  • Bench-top
  • 10°C to 40°C
  • Connecting wires, user manual
  • General purpose SCR (TYN612 or equivalent)
  • Provided for easy measurement and observation

SCR Characteristics Apparatus Trade Information

  • 5 Unit Per Week
  • 4-5 Days
  • Asia, Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Africa, Central America
  • All India

Product Description

SCR Characteristics Apparatus with Regulated Power Supply (AE 221 )

Objective :To plot Anode current Vs Anode Cathode Voltage Characteristics. Gate Characteristics (Open Gate), Gate Characteristics (Gate connected).

Features :Instrument comprises of two DC Regulated Power Supplies 0-30VDC/150mA & 0-1VDC/150mA, three round meters for voltage & current measurement, SCR 2P4M mounted behind the panel, connections of Supplies, Meters & SCR brought out at 4mm Sockets.


Accurate SCR Parameter Measurement

Designed for precise analysis of SCR static characteristics, the unit features highly accurate analog and digital meters. The variable output voltage and current range allow comprehensive examination of V-I characteristics, promoting a thorough understanding of SCR behavior for both students and professionals.


Enhanced Safety and Durability

With integrated short circuit and overload protection, the SCR Characteristics Apparatus ensures reliable usage in experimental settings. Its robust construction using hard plastic and superior quality components provides protection and longevity, making it suitable for repeated use in educational and industrial labs.


User-Friendly, Compact Design

The bench-top apparatus offers an accessible interface, complete with labeled test points and secured connections for effortless operation and measurement. Lightweight and portable, its dimensions (350 mm x 275 mm x 125 mm) make it easy to fit on any standard laboratory desk or workspace.

FAQs of SCR Characteristics Apparatus:


Q: How does the SCR Characteristics Apparatus facilitate measurement of V-I characteristics?

A: The apparatus utilizes a general-purpose SCR along with variable voltage and current supplies, test points for direct probing, and dual range analog/digital meters. This setup allows users to accurately measure and analyze various points on the SCRs V-I curve under different conditions.

Q: What safety features are included in the SCR Characteristics Apparatus?

A: To ensure safe operation, the device is equipped with short circuit and overload protection circuits. These prevent accidental damage to the SCR or other components during experiments, promoting safe usage for students and laboratory personnel.

Q: When should the SCR Characteristics Apparatus be used during an electronics curriculum?

A: This apparatus is typically used during practical sessions when covering power electronics, semiconductor devices, or during dedicated experiments focusing on studying the static and dynamic performance characteristics of SCRs in laboratory courses.

Q: Where can the SCR Characteristics Apparatus be installed or used?

A: Designed with a compact, bench-top format, the apparatus is ideal for installation in electronics laboratories, research centers, technical institutes, and training facilities equipped with standard 230V AC mains supply.

Q: What is the process for analyzing SCR operation with this apparatus?

A: Connect the provided wires as per the user manual, use the potentiometers to set desired voltage and current, and observe reading changes via the built-in meters. Measurement points make it easy to monitor the SCR response at different stages, aiding in detailed analysis and report generation.

Q: How does the built-in detector circuit benefit SCR experimentation?

A: The in-built detector circuit immediately identifies SCR conduction and turn-off states, ensuring precise and reliable observation during experiments. This greatly enhances the learning experience by enabling real-time monitoring of SCR behavior.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Analog Lab Training Modules' category