Function Generator 2Hz to 20MHz

Function Generator 2Hz to 20MHz

Product Details:

  • Voltage 220 V
  • Power 220V AC, 50 Hz
  • Display Digital frequency display
  • Usage Laboratory, Testing, R&D, Educational Purposes
  • Product Type Function Generator
  • Material Metal enclosure
  • Design Bench-top compact design
  • Click to view more
X

Function Generator 2Hz to 20MHz Price And Quantity

  • 1 Unit
  • Up to 20V p-p (open circuit)
  • 20% to 80% (adjustable)
  • Yes, adjustable
  • 0°C to 50°C
  • 2Hz to 20MHz
  • 50 Ohm (typical)
  • Manual sweep available
  • Mains cord, User manual
  • BNC
  • < 50ns
  • Sine, Square, Triangle, Ramp, Pulse
  • 10 dB, 20 dB fixed
  • No modulation

Function Generator 2Hz to 20MHz Product Specifications

  • Function Generator
  • High accuracy output with low distortion
  • 280 x 215 x 80 mm
  • Metal enclosure
  • 220V AC, 50 Hz
  • 220 V
  • Approx. 2.5 kg
  • Bench-top compact design
  • AC Mains
  • Laboratory, Testing, R&D, Educational Purposes
  • Digital frequency display
  • Up to 20V p-p (open circuit)
  • 20% to 80% (adjustable)
  • Yes, adjustable
  • 0°C to 50°C
  • 2Hz to 20MHz
  • 50 Ohm (typical)
  • Manual sweep available
  • Mains cord, User manual
  • BNC
  • < 50ns
  • Sine, Square, Triangle, Ramp, Pulse
  • 10 dB, 20 dB fixed
  • No modulation

Function Generator 2Hz to 20MHz Trade Information

  • 5 Unit Per Week
  • 4-5 Days
  • Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Africa, Central America, Asia
  • All India

Product Description

Function Generator 2Hz to 20MHz

TECHNICAL SPECIFICATIONS
  • Frequency Range : 0.2Hz - 20MHz. in decadic steps variable control between steps.
  • Functions : Sine, square, Triangle,Ramp, Pulse & TTL pulse output.
  • Display Frequency : Digital (4 digit 7 segment display). Automatic decimal position
  • Accuracy Frequency : Better than + 1% + 1digit.
  • Amplitude
  • Open circuit: 20 V p-p (Sine ,Square, Triangle) + 5 V in DC mode.
  • into 50 ohms: 10Vp-p (Sine ,Square, Triangle) Peak amp + DC offset < +10V
  • Attenuator : 2 steps attenuators 20dB each and vernier fine 20dB
  • Amplitude flatness upto 3MHz : + 0.5dB above 3MHz : + 1dB
  • DC Offset(switchable): Upto + 5V + 5%into open circuit.
  • + 2.5V + 5% into into 50 ohm.
  • Output Impedance : 50 ohms & 600 Ohms + 10%
  • (Switchable)



Versatile Waveform Output

This function generator supports various output waveforms including sine, square, triangle, ramp, and pulse. Its adaptability enables comprehensive testing for electronic circuits and educational experiments. The adjustable duty cycle and DC offset further enhance the utility for versatile signal simulation, making it a valuable tool for laboratories, R&D units, and educational institutions.


Precision and Reliability

Engineered for high accuracy and low distortion, the generator delivers dependable performance across its 2Hz to 20MHz frequency range. The digital frequency display ensures precise readings, while fixed attenuation levels allow you to tailor output amplitudes. Its robust metal enclosure and compact design make it suitable for demanding bench-top use.


User-Friendly and Comprehensive

Manual sweep function, BNC connectors, and intuitive controls offer straightforward operation. The inclusion of a mains cord and user manual ensures users can quickly set up and start generating signals. Operating on standard 220V AC, this device meets the needs of professionals and learners alike for consistent and efficient signal generation.

FAQs of Function Generator 2Hz to 20MHz:


Q: How do I select and adjust the output waveform on this function generator?

A: Waveform selection is performed via the front panel controls, allowing you to choose from sine, square, triangle, ramp, and pulse outputs. Further adjustments such as duty cycle and DC offset can be made using the respective control knobs to match your test requirements.

Q: What are the main benefits of using this function generator in a laboratory or educational setting?

A: This device offers a broad frequency range (2Hz20MHz), multiple waveform outputs, high output amplitude, and low distortion. Its accuracy and versatility make it ideal for circuit testing, research experiments, and practical demonstrations in both laboratories and classrooms.

Q: When should I utilize the manual sweep function?

A: The manual sweep function is beneficial when you need to observe circuit responses across frequencies, such as during frequency response testing, component characterization, or educational demonstrations that illustrate the impact of changing signal frequencies.

Q: Where is the output available and what type of connector is used?

A: Signal output is delivered via a BNC connector located on the front panel, providing a secure and standardized connection for lab instrumentation and test equipment.

Q: What process should I follow to control signal amplitude and attenuation?

A: Amplitude can be adjusted up to 20V p-p (open circuit) using the amplitude knob. Fixed attenuation options of 10 dB and 20 dB are available for more precise output control, making it suitable for sensitive circuits or when integration into testing setups is required.

Q: How do I use the DC offset and duty cycle adjustments?

A: To add a DC offset to your signal, simply use the offset control knob, which allows for fine-tuning tailored to your application. The duty cycle for square and pulse waveforms is adjustable between 20% and 80%, letting you modify pulse width easily for specific tests.

Q: What accessories are included, and how do they support usage?

A: The function generator comes with a mains cord and a user manual. The mains cord ensures immediate setup with standard AC mains, while the user manual provides comprehensive instructions for operation, waveform adjustments, and safety information.

Tell us about your requirement