Audio Frequency Function Generator 1Hz to 100KHz

Audio Frequency Function Generator 1Hz to 100KHz

Product Details:

  • Display Analog Frequency Dial
  • Power 5W (Typical)
  • Usage Laboratory and Audio Testing
  • Voltage 220V AC, 50Hz
  • Product Type Audio Frequency Function Generator
  • Material Powder Coated Metallic Enclosure
  • Design Bench-Top Rectangular Cabinet
  • Click to view more
X

Audio Frequency Function Generator 1Hz to 100KHz Price And Quantity

  • 1 Unit
  • 600 Ohms
  • Sine, Triangle, Square
  • Manual Frequency Sweeping
  • Provided
  • Less than 0.5 s
  • Standard Banana Jacks
  • Grey/Blue
  • Up to 10V peak-to-peak (adjustable)
  • Variable
  • Operating Temperature 0C to 45C
  • Less than 1% (Sine Wave below 10kHz)
  • 1Hz to 100kHz (Continuous)

Audio Frequency Function Generator 1Hz to 100KHz Product Specifications

  • Powder Coated Metallic Enclosure
  • 5W (Typical)
  • Bench-Top Rectangular Cabinet
  • Audio Frequency Function Generator
  • Analog Frequency Dial
  • Approx. 3 Kg
  • 235mm x 110mm x 265mm
  • Not Applicable (Operates from mains supply)
  • AC Mains
  • 220V AC, 50Hz
  • Laboratory and Audio Testing
  • 2% (Below 100kHz)
  • 600 Ohms
  • Sine, Triangle, Square
  • Manual Frequency Sweeping
  • Provided
  • Less than 0.5 s
  • Standard Banana Jacks
  • Grey/Blue
  • Up to 10V peak-to-peak (adjustable)
  • Variable
  • Operating Temperature 0C to 45C
  • Less than 1% (Sine Wave below 10kHz)
  • 1Hz to 100kHz (Continuous)

Audio Frequency Function Generator 1Hz to 100KHz Trade Information

  • 5 Unit Per Week
  • 4-5 Days
  • Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Central America, Asia, Africa
  • All India

Product Description

Audio Frequency Function Generator 1Hz to 100KHz (AE 511)
  • Wave shapes : Sine, square & triangular waves selectable using band switch.
  • Frequency range : 1 hz to 100 khz setable using fine & coarse controls
  • Accuracy :  3 % on all ranges, amplitude for sine wave output : 10 V p/p.



Versatile Waveform Output

This function generator delivers sine, triangle, and square waveforms, allowing users to cover a comprehensive range of test scenarios in audio and laboratory settings. All waveforms are available across the entire frequency range, enhancing its utility for signal generation and analysis.


Precision and Control

With an analog frequency dial and variable amplitude adjustment up to 10V peak-to-peak, this generator supports precise frequency setting and output control. Its accuracy remains within 2% below 100kHz, critical for reliable measurement and experimentation.


Safe and Durable Design

Housed in a powder-coated metallic cabinet, the generator offers robust physical protection. Integrated fuse protection and compliance with operating conditions from 0C to 45C make it safe for extended use in professional environments. Standard AC mains operation ensures consistent performance.

FAQs of Audio Frequency Function Generator 1Hz to 100KHz:


Q: How do I adjust the output frequency and waveform on this function generator?

A: The output frequency is set using the analog frequency dial, which allows continuous adjustment across the 1Hz to 100kHz range. You can choose between sine, triangle, and square waveforms with the respective selector switches provided on the front panel.

Q: What are the main benefits of using this generator for laboratory and audio testing?

A: It offers wide frequency coverage, low distortion, adjustable amplitude, and multiple waveforms, making it ideal for audio circuit characterization, filter testing, and general signal simulation. Its precision and reliability contribute to accurate experimental results.

Q: Where can this function generator be set up and operated effectively?

A: Designed as a bench-top device, it is best suited for laboratories, audio testing rooms, educational institutions, and industrial environments. Its robust enclosure and standard banana jacks allow for easy integration into typical testing setups.

Q: What process should I follow for safely connecting and using the output?

A: Simply connect the output terminals using standard banana jacks, ensuring the device is powered from a 220V AC supply. Adjust amplitude and frequency as needed, while observing recommended operating temperatures. Fuse protection provides additional safety during use.

Q: When should I use manual frequency sweeping, and how does it work?

A: Manual frequency sweeping is effective when you need to observe system response over a range of frequencies, such as during audio equipment calibration. This function is controlled directly from the front panel for smooth frequency transitions.

Q: What measures are in place for user safety and device protection?

A: Fuse protection is built in to safeguard against electrical faults. The powder-coated metallic enclosure, combined with specified operating temperature limits, ensures safe and durable operation under standard laboratory conditions.